Specifications:
Current:-50 AmpsAccuracy 1.5% at 25 deg. C.
Voltage:-600 VoltsAccuracy 1.5% at 25 deg. C.
Note: other ranges available to order
Irradiance:-Reference calibrated crystalline cell
Array Temperature:-K type thermocouple probe
Data Acquisition System:
Operation:
The software prompts the operator to input user information regarding the site, type of array, name and any reference number and date. The system acquires the I-V curve data and then the data is displayed and stored on the laptop PC for future processing. The tester measures the following I/V characteristics of PV arrays:• Short circuit current (Isc) • Open circuit voltage (Voc) • Current at max. power (Impp) • Voltage at max. power (Vmpp) • Power at max. Power (Pmpp) • Fill factor (FF) • Array temperature • Irradiance on plane of array • Display normalised I-V curve • Display normalised P-V curve
Note: EETS reserves the right to change specification without notice.